{"id":1776,"date":"2026-07-27T20:48:26","date_gmt":"2026-07-27T18:48:26","guid":{"rendered":"https:\/\/gliukozesmatuoklis.lt\/?page_id=1776"},"modified":"2026-07-27T20:54:39","modified_gmt":"2026-07-27T18:54:39","slug":"naudojimo-instrukcija","status":"publish","type":"page","link":"https:\/\/gliukozesmatuoklis.lt\/en\/naudojimo-instrukcija\/","title":{"rendered":"Naudojimo instrukcija"},"content":{"rendered":"<p>\u0160iame puslapyje pateikiama gamintojo parengta <a href=\"\/en\/prekes-kategorija\/gliukozes-jutikliai\/\">LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio<\/a> (modelis GX-01S) naudojimo instrukcija lietuvi\u0173 kalba. Tekstas pateikiamas taip, kaip jis pateiktas su gaminiu; original\u016bs instrukcijos puslapiai \u2014 <a href=\"#originalas\">puslapio apa\u010dioje<\/a>.<\/p>\n<p style=\"background:#E8F5E9;border-left:4px solid #2E7D32;padding:14px 18px;margin:0 0 24px;border-radius:4px\"><strong>PRIE\u0160 PRAD\u0116DAMI NAUDOTI NUOLATINIO GLIUKOZ\u0116S STEB\u0116JIMO SISTEM\u0104, ATID\u017dIAI PERSKAITYKITE NAUDOJIMO INSTRUKCIJ\u0104.<\/strong><\/p>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Produkto informacija<\/h2>\n<div style=\"overflow-x:auto\">\n<table style=\"width:100%;border-collapse:collapse\">\n<tbody>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;width:220px\"><strong>Produkto pavadinimas<\/strong><\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklis<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\"><strong>Produkto modelis<\/strong><\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">GX-01S<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\"><strong>Naudojama su<\/strong><\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">RC2107, RC2109 CGM program\u0117le<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Naudojimo indikacijos<\/h2>\n<p>Nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklis yra realaus laiko, nuolatin\u0117s gliukoz\u0117s steb\u0117jimo prietaisas. Kai sistema naudojama kartu su suderinamais prietaisais, skirta nuolatiniam gliukoz\u0117s kiekiui intersticiniame skystyje matuoti diabetu sergantiems asmenims nuo 2 met\u0173 ir vyresniems. Ji sukurta tam, kad pakeist\u0173 pir\u0161to d\u016brio kraujo gliukoz\u0117s tyrim\u0105 priimant sprendimus d\u0117l diabeto gydymo.<\/p>\n<p>Sistemos rezultat\u0173 interpretavimas tur\u0117t\u0173 b\u016bti pagr\u012fstas gliukoz\u0117s tendencijomis ir keliais nuosekliais rodmenimis laikui b\u0117gant. Sistema taip pat aptinka tendencijas ir seka modelius bei padeda aptikti hiperglikemijos ir hipoglikemijos epizodus, palengvindama tiek \u016bmin\u012f, tiek ilgalaik\u012f gydymo koregavim\u0105.<\/p>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">1 \u017eingsnis. \u012ediekite \u201eLinX CGM\u201c program\u0117l\u0119<\/h2>\n<p>Atsisi\u0173skite LinX CGM program\u0117l\u0119 i\u0161 \u201eGoogle Play\u201c arba \u201eApp Store\u201c. Program\u0117li\u0173 parduotuv\u0117s paie\u0161koje \u012fveskite <strong>LinX CGM<\/strong>. I\u0161sam\u016bs diegimo \u017eingsniai su ekrano vaizdais \u2014 puslapyje <a href=\"\/en\/aplikacija\/\">Kaip \u012fsira\u0161yti program\u0117l\u0119<\/a>.<\/p>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">2 \u017eingsnis. U\u017eregistruokite paskyr\u0105<\/h2>\n<p>Sukurkite LinX paskyr\u0105 naudodami galiojant\u012f el. pa\u0161to adres\u0105.<\/p>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">3 \u017eingsnis. U\u017esid\u0117kite jutikl\u012f<\/h2>\n<h3 style=\"margin:20px 0 8px\">Apra\u0161ymas<\/h3>\n<p>Jutiklis yra jutiklio aplikatoriaus viduje. Vadovaukit\u0117s instrukcijomis, kad paruo\u0161tum\u0117te ir u\u017ed\u0117tum\u0117te jutikl\u012f ant \u017easto galin\u0117s pus\u0117s.<\/p>\n<p>Jutiklis turi ma\u017e\u0105, lankst\u0173 galiuk\u0105, kuris \u012fvedamas tiesiai po oda. Jutikl\u012f galima ne\u0161ioti iki 15 dien\u0173.<\/p>\n<div style=\"overflow-x:auto\">\n<table style=\"width:100%;border-collapse:collapse\">\n<tbody>\n<tr>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;background:#E8F5E9;color:#2E7D32;white-space:nowrap;vertical-align:top;font-weight:700;width:120px\">Veiksmas 1<\/td>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;vertical-align:top\">Pasirinkite \u017easto galin\u0119 pus\u0119 kaip \u012fvedimo viet\u0105 (venkite i\u0161orin\u0117s \u017easto raumens dalies).<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;background:#E8F5E9;color:#2E7D32;white-space:nowrap;vertical-align:top;font-weight:700;width:120px\">Veiksmas 2<\/td>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;vertical-align:top\">Dezinfekuokite \u012fvedimo viet\u0105 alkoholio servet\u0117le ir palaukite, kol ji visi\u0161kai nud\u017eius.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;background:#E8F5E9;color:#2E7D32;white-space:nowrap;vertical-align:top;font-weight:700;width:120px\">Veiksmas 3<\/td>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;vertical-align:top\">Atsukite aplikatoriaus dangtel\u012f ir atid\u0117kite j\u012f \u012f \u0161al\u012f.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;background:#E8F5E9;color:#2E7D32;white-space:nowrap;vertical-align:top;font-weight:700;width:120px\">Veiksmas 4<\/td>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;vertical-align:top\">Tiksliai sulygiuokite aplikatoriaus ang\u0105 su \u012fvedimo vieta ir stipriai prispauskite aplikatori\u0173 prie odos. Paspauskite balt\u0105 implantavimo mygtuk\u0105. I\u0161girdus spyruokl\u0117s gr\u012f\u017eimo gars\u0105, jutiklis bus \u012fvestas po oda, o d\u016brio adata automati\u0161kai \u012fsitrauks atgal \u012f aplikatori\u0173.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;background:#E8F5E9;color:#2E7D32;white-space:nowrap;vertical-align:top;font-weight:700;width:120px\">Veiksmas 5<\/td>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;vertical-align:top\">\u0160velniai atitraukite jutiklio aplikatori\u0173 nuo k\u016bno. Jutiklis turi likti pritvirtintas prie odos.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;background:#E8F5E9;color:#2E7D32;white-space:nowrap;vertical-align:top;font-weight:700;width:120px\">Veiksmas 6<\/td>\n<td style=\"padding:10px;border-bottom:1px solid #E0E0E0;text-align:left;vertical-align:top\">\u012esitikinkite, kad jutiklis tvirtai pritvirtintas. Pir\u0161tais prispauskite jutiklio kra\u0161tus, kad i\u0161vengtum\u0117te rauk\u0161li\u0173 ar at\u0161okimo.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:24px 0\"><img decoding=\"async\" src=\"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-uzdejimas-6-zingsniu.jpg\" alt=\"LinX CGM jutiklio u\u017ed\u0117jimas: \u0161e\u0161i veiksmai nuo vietos pasirinkimo iki jutiklio kra\u0161t\u0173 prispaudimo\" style=\"max-width:100%;height:auto\" loading=\"lazy\" \/><figcaption style=\"font-size:14px;color:#555;margin-top:8px\">Jutiklio u\u017ed\u0117jimo veiksmai 1\u20136 (gamintojo instrukcijos iliustracija).<\/figcaption><\/figure>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">4 \u017eingsnis. Susiekite jutikl\u012f su LinX CGM program\u0117le<\/h2>\n<ul>\n<li>Prisijunkite prie LinX CGM program\u0117l\u0117s.<\/li>\n<li>\u012esitikinkite, kad telefono Bluetooth ry\u0161ys \u012fjungtas.<\/li>\n<li>Pagrindiniame ekrane paspauskite \u201eSuporuoti\u201c (Pair).<\/li>\n<li>Pasirinkite ir patvirtinkite teising\u0105 jutiklio SN numer\u012f i\u0161 netoliese esan\u010di\u0173 \u012frengini\u0173 s\u0105ra\u0161o. (\u012esitikinkite, kad pasirinktas SN numeris sutampa su numeriu ant pakuot\u0117s ir aplikatoriaus dangtelio.)<\/li>\n<li>Palaukite s\u0117kmingo suporavimo.<\/li>\n<\/ul>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Kontraindikacijos<\/h2>\n<p>Nuolatinio gliukoz\u0117s steb\u0117jimo sistema turi b\u016bti nuimta prie\u0161 magnetinio rezonanso tomografijos (MRT) tyrim\u0105.<\/p>\n<p>Ned\u0117v\u0117kite nuolatinio gliukoz\u0117s steb\u0117jimo jutiklio kompiuterin\u0117s tomografijos (KT) tyrimo metu ar atliekant auk\u0161to da\u017enio elektrinio \u0161ildymo (diatermijos) proced\u016bras.<\/p>\n<p>Vartojant didesn\u0119 nei maksimali leistina acetaminofeno (paracetamolio) doz\u0119 (pvz., daugiau nei 1 g kas 6 valandas suaugusiesiems), nuolatinio gliukoz\u0117s steb\u0117jimo jutiklio rodmenys gali b\u016bti paveikti ir rodyti didesnes reik\u0161mes nei tikrosios.<\/p>\n<p>Nuolatinio gliukoz\u0117s steb\u0117jimo sistema nebuvo vertinta \u0161ioms asmen\u0173 grup\u0117ms:<\/p>\n<ul>\n<li>n\u0117\u0161\u010dioms moterims;<\/li>\n<li>pacientams, kuriems taikoma peritonin\u0117 dializ\u0117;<\/li>\n<li>pacientams su implantuotais \u0161irdies stimuliatoriais;<\/li>\n<li>pacientams, turintiems kraujo kre\u0161\u0117jimo sutrikim\u0173 arba vartojantiems antikoaguliantus.<\/li>\n<\/ul>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Atsargumo priemon\u0117s<\/h2>\n<ul>\n<li>Draud\u017eiama modifikuoti nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistem\u0105.<\/li>\n<li>Neautorizuoti pakeitimai gali sukelti prietaiso veikimo sutrikimus arba padaryti j\u012f netinkamu naudoti.<\/li>\n<li>Prie\u0161 naudojant \u0161\u012f gamin\u012f, b\u016btina perskaityti naudojimo instrukcij\u0105.<\/li>\n<li>Nuotolinio gliukoz\u0117s steb\u0117jimo sistemoje yra smulki\u0173 dali\u0173, kurios gali b\u016bti pavojingos prarijus.<\/li>\n<li>Esant greitiems gliukoz\u0117s poky\u010diams kraujyje (daugiau nei 0,1 mmol\/l per minut\u0119), intersticinio skys\u010dio gliukoz\u0117s reik\u0161m\u0117s gali neatitikti kraujo gliukoz\u0117s reik\u0161mi\u0173.<\/li>\n<li>Kai gliukoz\u0117s kiekis kraujyje greitai ma\u017e\u0117ja, jutiklis gali rodyti didesnes reik\u0161mes nei kraujo gliukoz\u0117s lygis.<\/li>\n<li>Kai gliukoz\u0117s kiekis kraujyje greitai did\u0117ja, jutiklis gali rodyti ma\u017eesnes reik\u0161mes. Tokiais atvejais jutiklio rodmenys turi b\u016bti patikrinti atliekant kraujo gliukoz\u0117s matavim\u0105 i\u0161 pir\u0161to.<\/li>\n<li>Jei b\u016btina patvirtinti hipoglikemij\u0105 ar art\u0117jan\u010di\u0105 hipoglikemij\u0105, nustatyt\u0105 pagal jutiklio rodmenis, reikia atlikti kraujo gliukoz\u0117s matavim\u0105 i\u0161 pir\u0161to.<\/li>\n<li>Sunki dehidratacija arba didelis skys\u010di\u0173 netekimas gali lemti netikslius rezultatus. \u012etarus dehidratacij\u0105, nedelsiant kreipkit\u0117s \u012f sveikatos prie\u017ei\u016bros specialist\u0105.<\/li>\n<li>Jei manote, kad nuotolinio gliukoz\u0117s steb\u0117jimo sistemos rodmenys yra netiksl\u016bs arba neatitinka simptom\u0173, atlikite kraujo gliukoz\u0117s matavim\u0105 arba kalibruokite jutikl\u012f. Jei problema i\u0161lieka \u2013 nuimkite ir pakeiskite jutikl\u012f.<\/li>\n<li>Nuotolinio gliukoz\u0117s steb\u0117jimo sistemos veikimas nebuvo vertintas naudojant kartu su kitais implantuojamais medicinos prietaisais, pavyzd\u017eiui, \u0161irdies stimuliatoriais.<\/li>\n<li>Jutiklio atsikabinimas arba nu\u0117mimas gali lemti tai, kad program\u0117l\u0117je nebus rodomi duomenys.<\/li>\n<li>Jei jutiklis sugenda, nebandykite jo taisyti patys.<\/li>\n<li>Gaminys yra atsparus vandeniui ir gali b\u016bti d\u0117vimas du\u0161o ar plaukimo metu, ta\u010diau jutiklio negalima panardinti \u012f vanden\u012f giliau nei 2 metrus ilgiau nei 1 valand\u0105.<\/li>\n<li>Nuotolinio gliukoz\u0117s steb\u0117jimo rodmenys turi b\u016bti naudojami tik kaip papildoma diabeto steb\u0117jimo priemon\u0117 ir neturi b\u016bti naudojami klinikinei diagnozei nustatyti.<\/li>\n<li>Nors buvo atlikti i\u0161sam\u016bs naudotoj\u0173 tyrimai sergant 1 ir 2 tipo cukriniu diabetu, tyrimuose nebuvo \u012ftrauktos moterys, sergan\u010dios gestaciniu diabetu.<\/li>\n<li>Jei gaminys neveikia tinkamai arba buvo pa\u017eeistas, nutraukite jo naudojim\u0105.<\/li>\n<\/ul>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Simbolika<\/h2>\n<div style=\"overflow-x:auto\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"text-align:left;padding:8px 10px;border-bottom:2px solid #2E7D32\">Reik\u0161m\u0117<\/th>\n<th style=\"text-align:left;padding:8px 10px;border-bottom:2px solid #2E7D32\">Simbolis<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Naudojimo instrukcija<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">\u017emogaus fig\u016bra, skaitanti atverst\u0105 knyg\u0105 su \u201ei\u201c \u017eenklu<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Gamintojas<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">gamyklos pastato piktograma<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Atmosferos sl\u0117gio ribojimas<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">nuo 700 hPa iki 1060 hPa<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">BF tipo taikomoji dalis<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">\u017emogaus fig\u016bra kvadratiniame r\u0117melyje<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Vienkartin\u0117 sterili barjerin\u0117 sistema su apsaugine pakuote<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">STERILE su rodykle<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Nenaudoti, jei pakuot\u0117 pa\u017eeista<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">perbraukta pa\u017eeistos pakuot\u0117s piktograma<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Partijos kodas (LOT)<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">LOT<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">MRT nesaugus<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">perbrauktas apskritimas su raid\u0117mis MR<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">\u012egaliotas atstovas Europos S\u0105jungoje<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">EU REP<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Temperat\u016bros ribos<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">nuo 2 \u00b0C iki 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Dr\u0117gm\u0117s ribos<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">nuo 10 % iki 90 %<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Nenaudoti pakartotinai<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">perbrauktas skaitmuo 2<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Atsargiai<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">trikampis su \u0161auktuku<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Pagaminimo data<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">gamyklos piktograma su data<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Tinkamumo naudoti data<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">sm\u0117lio laikrod\u017eio piktograma<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Serijos numeris<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">SN<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Unikalus prietaiso identifikatorius<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">UDI<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Elektros ir elektronin\u0117s \u012frangos atliekos<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">perbraukta \u0161iuk\u0161liad\u0117\u017e\u0117 su ratukais<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">CE \u017eenklinimas<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">CE 0197<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Medicinos prietaisas<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">MD<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left\">Apsauga nuo dulki\u0173 ir vandens<\/td>\n<td style=\"padding:8px 10px;border-bottom:1px solid #E0E0E0;text-align:left;color:#555\">IP68<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:24px 0\"><img decoding=\"async\" src=\"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-simbolika.jpg\" alt=\"LinX instrukcijos simboli\u0173 lentel\u0117 su piktogramomis: MRT nesaugus, CE 0197, MD, IP68, LOT, SN, UDI\" style=\"max-width:100%;height:auto\" loading=\"lazy\" \/><figcaption style=\"font-size:14px;color:#555;margin-top:8px\">Simboli\u0173 atvaizdai gamintojo instrukcijoje.<\/figcaption><\/figure>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Gamintojas ir \u012fgaliotas atstovas<\/h2>\n<p><strong>Gamintojas:<\/strong> MicroTech Medical (Hangzhou) Co., Ltd.<br \/>No.108 Liuze St., Cangqian, Yuhang District, Hangzhou, 311121 Zhejiang, P.R. China<\/p>\n<p><strong>\u012egaliotas atstovas Europos S\u0105jungoje (EU REP):<\/strong> Lotus NL B.V.<br \/>Koningin Julianaplein 10, 1e Verd, 2595AA, The Hague, Netherlands<\/p>\n<p><strong>\u017denklinimas:<\/strong> CE 0197 \u00b7 MD (medicinos prietaisas) \u00b7 IP68<\/p>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\" id=\"originalas\">Original\u016bs instrukcijos puslapiai<\/h2>\n<p>Toliau \u2014 gamintojo instrukcijos puslapiai tokie, kokie pateikiami su gaminiu. Paspaud\u0119 atversite didesn\u012f vaizd\u0105.<\/p>\n<figure style=\"margin:24px 0\"><a href=\"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-instrukcija-1psl.jpg\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-instrukcija-1psl.jpg\" alt=\"Instrukcijos 1 puslapis: indikacijos, 1\u20134 \u017eingsniai, kontraindikacijos\" style=\"max-width:100%;height:auto;border:1px solid #E0E0E0\" loading=\"lazy\" \/><\/a><figcaption style=\"font-size:14px;color:#555;margin-top:8px\">Instrukcijos 1 puslapis: indikacijos, 1\u20134 \u017eingsniai, kontraindikacijos.<\/figcaption><\/figure>\n<figure style=\"margin:24px 0\"><a href=\"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-instrukcija-2psl.jpg\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-instrukcija-2psl.jpg\" alt=\"Instrukcijos 2 puslapis: atsargumo priemon\u0117s, simbolika, gamintojas\" style=\"max-width:100%;height:auto;border:1px solid #E0E0E0\" loading=\"lazy\" \/><\/a><figcaption style=\"font-size:14px;color:#555;margin-top:8px\">Instrukcijos 2 puslapis: atsargumo priemon\u0117s, simbolika, gamintojas.<\/figcaption><\/figure>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Da\u017eni klausimai<\/h2>\n<h3 style=\"margin:20px 0 8px\">Kiek laiko galima ne\u0161ioti vien\u0105 jutikl\u012f?<\/h3>\n<p>Jutikl\u012f galima ne\u0161ioti iki 15 dien\u0173 \u2014 taip nurodyta gamintojo instrukcijoje.<\/p>\n<h3 style=\"margin:20px 0 8px\">Ar galima maudytis su jutikliu?<\/h3>\n<p>Gaminys yra atsparus vandeniui ir gali b\u016bti d\u0117vimas du\u0161o ar plaukimo metu, ta\u010diau jutiklio negalima panardinti \u012f vanden\u012f giliau nei 2 metrus ilgiau nei 1 valand\u0105.<\/p>\n<h3 style=\"margin:20px 0 8px\">K\u0105 daryti prie\u0161 MRT ar KT tyrim\u0105?<\/h3>\n<p>Prie\u0161 magnetinio rezonanso tomografijos (MRT) tyrim\u0105 sistem\u0105 b\u016btina nuimti. Jutiklio taip pat negalima d\u0117v\u0117ti kompiuterin\u0117s tomografijos (KT) tyrimo metu ar atliekant diatermijos proced\u016bras.<\/p>\n<h3 style=\"margin:20px 0 8px\">K\u0105 daryti, jei rodmenys neatitinka savijautos?<\/h3>\n<p>Jei manote, kad rodmenys netiksl\u016bs arba neatitinka simptom\u0173, atlikite kraujo gliukoz\u0117s matavim\u0105 i\u0161 pir\u0161to arba kalibruokite jutikl\u012f. Jei problema i\u0161lieka \u2014 nuimkite ir pakeiskite jutikl\u012f.<\/p>\n<h2 style=\"color:#2E7D32;margin:32px 0 12px;line-height:1.3\">Kur kreiptis<\/h2>\n<p>Kilus klausim\u0173 d\u0117l jutiklio naudojimo, kalibravimo ar program\u0117l\u0117s \u2014 \u017er. <a href=\"\/en\/duk\/\">da\u017eniausiai u\u017eduodamus klausimus<\/a> ir <a href=\"\/en\/kalibracija\/\">kalibracijos paai\u0161kinim\u0105<\/a> arba susisiekite <a href=\"\/en\/kontaktai\/\">kontakt\u0173 puslapyje<\/a> nurodytais b\u016bdais.<\/p>\n<p style=\"background:#E8F5E9;border-left:4px solid #2E7D32;padding:14px 18px;margin:0 0 24px;border-radius:4px;border-left-color:#9E9E9E;background:#F5F5F5;margin-top:32px;font-size:14px\">\u0160i informacija skirta tik \u0161vietimui ir nepakei\u010dia gydytojo ar vaistininko konsultacijos. Prie\u0161 keisdami diabeto gydym\u0105 ar insulino doz\u0119, pasitarkite su sveikatos prie\u017ei\u016bros specialistu. Kilus abejoni\u0173 d\u0117l rodmen\u0173, matuokite gliukoz\u0119 i\u0161 pir\u0161to. Medicinos priemon\u0119 naudokite pagal gamintojo (MicroTech Medical) instrukcij\u0105. Individual\u016bs rezultatai gali skirtis.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0160iame puslapyje pateikiama gamintojo parengta LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio (modelis GX-01S) naudojimo instrukcija lietuvi\u0173 kalba. Tekstas pateikiamas taip, kaip jis pateiktas su gaminiu;&#8230;<\/p>","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1776","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.1 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>LinX CGM naudojimo instrukcija (GX-01S) - Gliukozesmatuoklis.lt<\/title>\n<meta name=\"description\" content=\"Oficiali LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio (GX-01S) naudojimo instrukcija lietuvi\u0161kai: u\u017ed\u0117jimas \u017eingsnis po \u017eingsnio, susiejimas su program\u0117le, kontraindikacijos ir atsargumo priemon\u0117s.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gliukozesmatuoklis.lt\/en\/naudojimo-instrukcija\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Naudojimo instrukcija\" \/>\n<meta property=\"og:description\" content=\"Oficiali LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio (GX-01S) naudojimo instrukcija lietuvi\u0161kai: u\u017ed\u0117jimas \u017eingsnis po \u017eingsnio, susiejimas su program\u0117le, kontraindikacijos ir atsargumo priemon\u0117s.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gliukozesmatuoklis.lt\/en\/naudojimo-instrukcija\/\" \/>\n<meta property=\"og:site_name\" content=\"Gliukozesmatuoklis.lt\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-27T18:54:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-uzdejimas-6-zingsniu.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/\",\"url\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/\",\"name\":\"LinX CGM naudojimo instrukcija (GX-01S) - Gliukozesmatuoklis.lt\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/linx-uzdejimas-6-zingsniu.jpg\",\"datePublished\":\"2026-07-27T18:48:26+00:00\",\"dateModified\":\"2026-07-27T18:54:39+00:00\",\"description\":\"Oficiali LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio (GX-01S) naudojimo instrukcija lietuvi\u0161kai: u\u017ed\u0117jimas \u017eingsnis po \u017eingsnio, susiejimas su program\u0117le, kontraindikacijos ir atsargumo priemon\u0117s.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/#primaryimage\",\"url\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/linx-uzdejimas-6-zingsniu.jpg\",\"contentUrl\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/linx-uzdejimas-6-zingsniu.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/naudojimo-instrukcija\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Naudojimo instrukcija\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/#website\",\"url\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/\",\"name\":\"Gliukozesmatuoklis.lt\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/#organization\",\"name\":\"Gliukozesmatuoklis.lt\",\"url\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/Logo.png\",\"contentUrl\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/Logo.png\",\"width\":166,\"height\":48,\"caption\":\"Gliukozesmatuoklis.lt\"},\"image\":{\"@id\":\"https:\\\/\\\/gliukozesmatuoklis.lt\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"LinX CGM naudojimo instrukcija (GX-01S) - Gliukozesmatuoklis.lt","description":"Oficiali LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio (GX-01S) naudojimo instrukcija lietuvi\u0161kai: u\u017ed\u0117jimas \u017eingsnis po \u017eingsnio, susiejimas su program\u0117le, kontraindikacijos ir atsargumo priemon\u0117s.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gliukozesmatuoklis.lt\/en\/naudojimo-instrukcija\/","og_locale":"en_US","og_type":"article","og_title":"Naudojimo instrukcija","og_description":"Oficiali LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio (GX-01S) naudojimo instrukcija lietuvi\u0161kai: u\u017ed\u0117jimas \u017eingsnis po \u017eingsnio, susiejimas su program\u0117le, kontraindikacijos ir atsargumo priemon\u0117s.","og_url":"https:\/\/gliukozesmatuoklis.lt\/en\/naudojimo-instrukcija\/","og_site_name":"Gliukozesmatuoklis.lt","article_modified_time":"2026-07-27T18:54:39+00:00","og_image":[{"url":"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-uzdejimas-6-zingsniu.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/","url":"https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/","name":"LinX CGM naudojimo instrukcija (GX-01S) - Gliukozesmatuoklis.lt","isPartOf":{"@id":"https:\/\/gliukozesmatuoklis.lt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/#primaryimage"},"image":{"@id":"https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/#primaryimage"},"thumbnailUrl":"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-uzdejimas-6-zingsniu.jpg","datePublished":"2026-07-27T18:48:26+00:00","dateModified":"2026-07-27T18:54:39+00:00","description":"Oficiali LinX nuolatin\u0117s gliukoz\u0117s steb\u0117jimo sistemos jutiklio (GX-01S) naudojimo instrukcija lietuvi\u0161kai: u\u017ed\u0117jimas \u017eingsnis po \u017eingsnio, susiejimas su program\u0117le, kontraindikacijos ir atsargumo priemon\u0117s.","breadcrumb":{"@id":"https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/#primaryimage","url":"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-uzdejimas-6-zingsniu.jpg","contentUrl":"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2026\/07\/linx-uzdejimas-6-zingsniu.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/gliukozesmatuoklis.lt\/naudojimo-instrukcija\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/gliukozesmatuoklis.lt\/"},{"@type":"ListItem","position":2,"name":"Naudojimo instrukcija"}]},{"@type":"WebSite","@id":"https:\/\/gliukozesmatuoklis.lt\/#website","url":"https:\/\/gliukozesmatuoklis.lt\/","name":"Gliukozesmatuoklis.lt","description":"","publisher":{"@id":"https:\/\/gliukozesmatuoklis.lt\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/gliukozesmatuoklis.lt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/gliukozesmatuoklis.lt\/#organization","name":"Gliukozesmatuoklis.lt","url":"https:\/\/gliukozesmatuoklis.lt\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/gliukozesmatuoklis.lt\/#\/schema\/logo\/image\/","url":"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2020\/09\/Logo.png","contentUrl":"https:\/\/gliukozesmatuoklis.lt\/wp-content\/uploads\/2020\/09\/Logo.png","width":166,"height":48,"caption":"Gliukozesmatuoklis.lt"},"image":{"@id":"https:\/\/gliukozesmatuoklis.lt\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/pages\/1776","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/comments?post=1776"}],"version-history":[{"count":2,"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/pages\/1776\/revisions"}],"predecessor-version":[{"id":1779,"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/pages\/1776\/revisions\/1779"}],"wp:attachment":[{"href":"https:\/\/gliukozesmatuoklis.lt\/en\/wp-json\/wp\/v2\/media?parent=1776"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}